Filter Results By:

Products

Applications

Manufacturers

Showing results: 76 - 85 of 85 items found.

  • 6U CompactPCI® Rear Transition Board for MIC-3395

    RIO-3315 - Advantech Co. Ltd.

    The RIO-3315 is the first Rear Transition Module (RTM) supporting PCIe connectivity to the main CPCI board enabling significant value-added features and extensions to next generation CPCI blades such as MIC-3395. The RIO-3315 supports: one PS/2 port, six USB ports, two RS-232 ports, two SATA ports, two Gigabit Ethernet ports, one digital and one integrated (digital/analog) DVI port. Three versions of RIO-3315 provide a choice of storage and LAN options. The RIO-3315-A1E with LSI1064E SAS controller supports a 4-port SAS controller with RAID, which allows switching between four internal SAS/SATA or four external MiniSAS ports. The RIO-3315-B1E supports SATA disk drives and SATA RAID via the QM67 PCH.

  • LXI Modular Chassis

    Pickering Interfaces Ltd.

    Our LXI modular chassis are available in 7-slot or 18-slot and support over 1,000 of our PXI modules, additionally our 2-Slot USB/LXI Chassis allows most of our 1 or 2-slot PXI modules to be controlled via USB or Ethernet. These range from: PXI general purpose relays, matrices, multiplexers and RF switches to special PXI switching functions such as fault/signal insertion. Also supported are a selection of T&M modules such as programmable resistors, digital I/O, power supplies, battery simulators and attenuators.

  • Physical Layer Switching Systems for copper LAN, WAN, DSL, Telco apps with RJ style connectors.

    RJ Series - Cytec Corp.

    The RJ Series of computer controlled switching systems are designed for physical layer switching of multiwire signals on RJ style connectors. Since the system uses mechanical relays it acts exactly like a piece of cable which makes it perfect for testing networks without altering the signals or regeneration. These systems are typically used for Ethernet LAN 10BaseT through 1000BaseT, DSL including ASML through GFAST, CAT5 through CAT6A cable testing, USB up to 2.0, RS232, RS422, RS485 up to 8 wire at 20 Mbps and many other applications switched over RJ45 connectors up to 8 wires. They may also be used as lab automation switches, network testing switches, patch panels, network redundancy switches or any number of physical layer applications.

  • Physical Layer Switching Systems for Copper LAN, WAN< DSL, Telco Apps with RJ Style Connectors

    RJ Series Switching Systems - Cytec Corp.

    The RJ Series of computer controlled switching systems are designed for physical layer switching of multiwire signals on RJ style connectors. Since the system uses mechanical relays it acts exactly like a piece of cable which makes it perfect for testing networks without altering the signals or regeneration. These systems are typically used for Ethernet LAN 10BaseT through 1000BaseT, DSL including ASML through GFAST, CAT5 through CAT6A cable testing, USB up to 2.0, RS232, RS422, RS485 up to 8 wire at 20 Mbps and many other applications switched over RJ45 connectors up to 8 wires. They may also be used as lab automation switches, network testing switches, patch panels, network redundancy switches or any number of physical layer applications.

  • High Speed Digital Analog

    JGB Consulting, Inc.

    The Automatic Test Equipment is designed to provide R&D and the Production floor with a high quality, reliable and easy to use Test Station comprised of COTS equipment from industry leading instrument manufactures. The measurement switching has low thermal offset allowing for micro volt measurements. The switching also accommodates both stimulus and measurement up to 5 Amps. Also to provide High Speed and Static Digital Stimulus and Response that covers LVDS, 3.3V, TTL, CMOS and Industrial logic families. For Serial communications there are SPI, I2C, RS232/485, USB and Ethernet. The system has nine programmable DC power supplies that are capable of powering both the UUT and the UUT interface separately. The system can interface with a variety of UUT’s via an ITA. Each system comes with the Imperial Test Executive, National Instruments TestStand, CVI, LabView and .NET Runtime.

  • 1226 Auto Switch/Distribution

    Precise Time and Frequency, Inc.

    To complement the range of high quality frequency and timing references, Precise Time and Frequency, Inc. has now introduced a new version of the ptf 1226A Auto Switch that includes an additional switch channel (now 3 channels total) of RF, and/or Digital, and/or Time Code, Auto Switching, and a full Ethernet/RS232 remote monitoring/control interface.In addition to the auto switching capability, the new ptf 1226 delivers up to thirty six channels of RF, Digital or Time Code frequency and/or timing references to critical applications such as Satellite Communications, Broadcasting, WiMax and others.Analog channels include a unique output level monitoring feature to provide remote indication of rms voltage output level.The unit can accept up to three pairs of inputs (usually from separate primary and backup sources), and provides monitoring of both the inputs and outputs for signal integrity. In addition RF channels include analog level monitoring. If the primary input on any auto switch channel fails, the unit will automatically switch to the backup input and indicate a primary signal fault.Full remote monitoring and control via RS232 and Ethernet interfaces includes telnet, http (web browser), and SNMP protocols.

  • GPON ONT

    ONT-1FE-1GE-RF-W - Hangzhou Softel Optic Co., Ltd.

    ONT-1FE-1GE-RF-W is fiber to the home multi service access XPON ONT. It’s based on the mature, stable, high cost performance EPON/GPON technology and has gigabit Ethernet switching, WDM and HFC technology. ONT-1FE-1GE-RF-W has a higher bandwidth, higher reliability, easy management and good quality of service (QoS) guarantee. It supports GPON and EPON two modes adaptive, can quickly and effectively distinguish between GPON and EPON systems, so normal operation under the current system. It adopts single fiber WDM technology with downlink wavelength 1550nm and 1490nm, uplink wavelength 1310nm . It only needs one-core fiber to transmit data and CATV service. ONT-1FE-1GE-RF-W can integration wireless function with meet 802.11 n/b/g technical standards,  It has external high gain directional antenna, the wireless transmission rate up   to 300Mbps. It has the characteristics of strong penetrating power and wide coverage. It can provide users with more efficient data transmission security.

  • UV Fluorescence Hydrogen Sulfide Analyzer

    Model T101 - Teledyne Monitor Labs

    The Model T101 H2S analyzer uses the proven UV fluorescence principle to measure hydrogen sulfide at levels commonly required for ambient air monitoring.The Model T101 is equipped with an internally mounted catalytic converter set at 315°C to convert H2S to SO2. A switching mode alternately measures H2S and SO2 while showing both readings concurrently on the front display.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T101 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ S​oftware. ​​

  • High Voltage Switching Systems

    HXV Series - Cytec Corp.

    HXV products are high voltage systems intened for Hi-pot / IR or High voltage switching. They can be configured to drive from 32 to 128 switch points per chassis and can be configured as multiplexer (1xN) or Matrix (NxM) configurations. Stand HXV chassis are used for signals up to 5000 VAC rms ( 7400 V peak ) and can carry up to 5 amps of current. Custom systems can be built up to 25KV. Most of the modules used in these systems are 1xN multiplexers or 2x4 matrix modules that can be combined to form larger multiplexers or matrices. Connector options for standard HXV include 5 way banaba jacks / binding posts, Shrouded Banana Jacks or SHV ( High voltage BNC) if you need to use a high voltage cable with a grounded shield for safety applications. Control options include 10/100BaseT Ethernet LAN, RS232, GPIB or optional manual control. Standard HXV systems use high voltage reed relays. Custom HXV systems up to 25KV use application specific relays and connectors from a variety of vendors based on required specifications.

  • UV Fluorescence Total Reduced Sulfur Analyzer

    Model T102 - Teledyne Monitor Labs

    The Model T102 TRS analyzer uses the proven UV fluorescence principle to measure Total Reduced Sulfur at levels commonly required for ambient air monitoring.The Model T102 uses a high temperature external converter set at 850°C to allow conversion of H2S, methyl mercaptan, dimethyldisulfide, and methyl-disulfide to SO2 at this temperature with efficiency greater than 98%. A switching option alternately measures TRS and SO2 while showing both readings concurrently on the front display.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T102 comes with NumaView ™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView ™ Software. ​​

Get Help